high
efficiency
isar HE
istor HE
excel HE
mini HE
combination & system storage boilers
Easier Navigation
page
12
page
8
page
26
page
38
istor HE
isar HE
excel HE
mini HE
3
introduction
4
an appliance for any application
5
product features
6
building regulation compliance
7
isar HE
8-11
istor HE
12-15
isar HE & istor HE fluing options
16-23
isar HE & istor HE
extras and accessories
24-25
excel HE
26-29
excel HE fluing options
30-35
excel HE extras and accessories
36-37
mini HE
38-41
mini HE fluing options
42-47
mini HE extras and accessories
48-49
high level flue outlet kit &
flue length graphs
50-51
supporting the installer
52
heat-only and system boiler options
53
notes
54-55
contents
Boiler accessory pages
Fluing option pages
Technical information
pages
Boiler output pages
Warranty
Easier Navigation
Throughout this brochure you will
find these symbols, making it
easier to access relevant
information.
Colour Code
Each boiler type has a colour
reference, these are:
isar HE
istor HE
excel HE
mini HE
introduction
Welcome to the range of HE combination boilers and system storage boilers from
Ideal. Throughout you will find that exceptional reliability has been our overriding
goal, and that the needs and expectations of the installer have been uppermost in
our considerations.
World class manufacturing
Ideal is one of the most respected names in the heating industry and the only
company in its field to have achieved `World Class Manufacturer' accreditation in the
prestigious IBM and London Business School UK manufacturing survey. For over 90
years we have been designing, refining and manufacturing appliances that are not
only trusted by the trade, but also relied upon by homeowners the length and
breadth of the country.
Our Hull-based factory is part of only 2% of all manufacturing sites in the UK that
have been independently judged as meeting the criteria for World Class
Manufacturing status, while our superior manufacturing facilities mean that we can
achieve `right first time' quality. In accordance with the company's World Class
status, we have adopted a programme of continuous improvement which ensures
that we constantly measure and monitor our performance to drive improvement
through innovation.
Dedicated to excellence
Everyone at Ideal is committed to delivering incomparable quality. Which is why
these products have been created to lead the way in innovative engineering, inspired
design and, above all else, exceptional standards of reliability.
Engineered for peace of mind
The components which have been used throughout the appliances are not only
manufactured to extremely high technical specifications, they are also common
across the range. As a result, the range of HE boilers are dependable, simple to
understand and require minimal maintenance and servicing.
To ensure this dependability, each of our boilers is also subjected to an
extraordinarily stringent regime of product assessment. This includes rigorous
application testing, as well as extensive laboratory and field trials.
What's more, the versatile design, which includes no compartment ventilation and
twin-pipe fluing, makes siting extremely flexible - meaning minimum hassle at no
extra cost for the installer.
Glossary of terms
FF
= fan-flued boiler
TRV
= thermostatic radiator valve
CH
= central heating
DHW = domestic hot water
PCB = printed circuit board
4
an appliance for any application
isar HE high-efficiency combination boiler
The Ideal isar HE high-efficiency combination boiler provides flexibility of siting,
together with advanced reliability, and has all the necessary components incorporated
into the product to enable easy installation to a fully pumped sealed system and
delivers mains pressure hot water.
The boiler is ideal for meeting the heating requirements for the majority of houses
and is available in three models, isar HE 24, HE 30, and HE 35.
istor HE high-efficiency boiler
A complete heating and unvented hot water system in a single unit gives a simple
and space saving installation. The Ideal istor HE high-efficiency boiler ensures low
running costs in conjunction with a fast recovery cylinder for large quantities of mains
pressure hot water. The istor HE is available in two models, the istor HE 260 and
HE 325.
excel HE high-efficiency combination boiler
The Ideal excel HE high-efficiency combination boiler is a straightforward design based
on familiar technology, offering easy installation and servicing. A range of 3 models,
the excel HE 24, HE 28 and HE 32 ensures there is a product for every situation.
mini HE high-efficiency combination boiler
Simple and robust designs using familiar technology providing easy installation
and servicing. A choice of three combination boilers, mini HE C24, HE C28 and
HE C32. These are all available in both natural gas and propane versions.
esprit HE high-efficiency combination boiler
A high specification range of three models 24, 30 & 35kW with flow rates to suit most
customers. Designed for ease of installation and use coupled with quality
components and build. The Esprit has built in as standard, many components
normally considered options and all with a 2 year warranty. A full range of controls
including RF programmable thermostats completes this outstanding range. For more
information on this product see the Ideal Esprit Brochure, you can download from
www.idealboilers.com
The boilers featured in this brochure cover applications where a combination boiler
is required, or for greater DHW requirements the istor HE will fulfil all demands.
Product solutions
for every system
5
Central Heating &
Unvented Storage System
Combination Boiler System
SEDBUK rating
A
SEDBUK rating
A
SEDBUK rating
B
SEDBUK rating
B
SEDBUK rating
A
6
Each of Ideal's HE combination and system storage boilers contains only those parts
that are necessary to deliver dependability and performance, or that make the
product easier to fit, operate or install. As a result, they all offer exceptional levels
of reliability and are easily maintained and serviced.
Common components
The isar HE and istor HE appliances share a wide number of common parts
making them easier to install, service, and maintain. These items include
components such as the gas valve, burner, venturi, fan, fluing system and controls.
Easy siting
All Ideal HE appliances are available with a wide range of flue options. These make
siting the boiler in the property easier as long flues can be used. It also makes
positioning the flue terminal easier.
Simple to fit and service
Because they have so much in common, fewer spares are required to maintain the
range of boilers.
All products are `self-adjusting' (other than the Ideal istor HE). This allows the installer
to fit the products without the need to make any alterations. The boilers, being fully
modulating, adjust themselves to the required output to meet the heating load.
Unprecedented reliability
We have introduced new test procedures which are comprised of a demanding series
of application tests to ensure that the boiler is fault-free.
We have never been tougher on ourselves or our products, and you will find that it
shows in the new standards of reliability which these products have attained.
product features
PRODUCT FEATURES
isar HE
istor HE
excel HE
mini HE
combination
system store
combination
combination
Diagnostic display
Kitchen cupboard fit*
n/a
n/a
n/a
No compartment ventilation required
Telescopic B pack flue
n/a
n/a
Optional programmer
Std.
Syphon kit available
n/a
Boiler stand-off kit
n/a
Remotely mountable user controls
(optional kit required)
n/a
n/a
*Note: When stand-off brackets are fitted, standard kitchen cupboard fit does not apply.
7
To comply with Part L of the Building Regulations 2005, Building (Scotland)
Regulations Section 6 or Northern Ireland Building Regulations Part F domestic
boilers are required to meet minimum SEDBUK ratings of 86%.
SEDBUK - Seasonal Efficiency of Domestic Boilers in the UK
The SEDBUK efficiency of a domestic boiler is an approved method of representing
the energy efficiency of a boiler under assumed typical operating conditions.
A boiler's efficiency is calculated using the SEDBUK rating (Seasonal Efficiency of
Domestic Boilers in the UK). This rating defines the average annual efficiency of a
domestic boiler achieved in typical domestic conditions, making reasonable
assumptions about pattern of usage, climate, control and other influences. SEDBUK
efficiencies are banded A-G (with A being the highest). The Ideal products isar HE
and istor HE are SEDBUK A rating approved with energy ratings over 90%. They are
all Energy Efficiency List recommended. The excel HE and mini HE ranges are
SEDBUK B rated with an efficiency greater than 86%.
These high-efficiency boiler ranges meet the requirements of the Building
Regulations 2005.
Ideal Boilers Ltd hereby declare that the boilers listed below meet the essential requirements for heating plant as described in:
Building Regulations - Part L1 2005, Building Standards (Scotland) Regulations - Section 6.
Band
SEDBUK range
A
Above 90%
B
86% 90%
C
82% 86%
D
78% 82%
E
74% 78%
F
70% 74%
G
Below 70%
building regulation compliance
Boiler
Range
Certificate No.
Notified body
Reference
istor HE
260/325
EC-87/04/034/M2
Advantica
0087
isar HE
24 - 35kW
EC-87/04/034/M2
Advantica
0087
excel HE
24 - 32kW
BP46
Advantica
0087
mini HE
24 - 32kW
BP0384
Gastec
0694
DETAILS OF COMPLIANCE
8
NB: UPWARD OR DOWNWARD PIPING OPTIONS ARE AVAILABLE
9
Application and usage
The isar HE benefits from being highly versatile and is perfectly suited to homes
where space is at a premium. This is enhanced by a standard telescopic flue and
twin-pipe fluing that gives excellent siting flexibility. The boiler is capable of meeting
the heating requirements for the majority of housing needs. Condensate drainage can
be overcome using the Ideal condensate pump kit.
The isar HE in operation
The isar HE is an automatically controlled, fanned flue high-efficiency boiler. The
boiler modulates its heat output to suit the demands of the heating load. It
incorporates a variable thermostat for CH temperature control, adjustable from 30ºC
to 82ºC. The use of a pre-mix burner allows control of gas input to the appliance
to be directly linked to fan speed. So, as the fan reduces speed to match heating
load, the gas valve maintains the correct proportional flow ensuring a high boiler
efficiency throughout its output range. The boiler incorporates all the necessary safety
features required to fit directly onto a sealed system. The isar HE also provides DHW
on demand via a high-efficiency secondary heat exchanger within the boiler casing.
The boiler's ability to modulate enables a stable DHW temperature to be obtained,
regardless of flow rate. An optional 7 day programmer with digital display enhances
the isar boiler range. With up to 3 periods per day, inbuilt default programmes and
battery back-up, this provides a simple economic means of system control.
The Ideal isar HE combination boiler
Excellent performance, reliability and ease of installation are trademarks of the
Ideal combination boiler. With its minimal components and slimline construction
the unit can be sited almost anywhere even in a standard kitchen cupboard, with
no additional compartment ventilation required. Other qualities such as a self-
adjusting feature for easy set up and an alpha-numeric diagnostic readout giving
coded appliance status, make this the most advanced combi boiler Ideal has ever
produced. In addition, its excellent performance and efficiency enables the
homeowner to save up to a third on gas bills.
isar HE
Combination Boiler System
isar HE
24-25
16-23
Please note: high level flue kit information is on pages 50-51
10-11
10-11
Optional programmer
Pictures are representational of installations but always check with your installer for guidance on pipework etc.
10
Cast aluminium-silicon
alloy heat exchanger
ensures tough,
dependable construction
and performance.
Built-in condensate
`S' trap with simple
connection makes
installation even easier.
Fully modulating product
with outputs from 8.8 to
24 kW to CH (30,000 to
80,000 Btu/h) suitable for
a wider range of
applications, and ensures
maximum efficiency
throughout the boiler's
modulation range.
Manifolds that house the
pump, pressure relief
valve, diverter valve,
thermostat and plate
heat exchanger mean
fewer connections
between boiler
components, improving
reliability and helping to
reduce overall product
weight.
Alpha-numeric diagnostic
readout gives essential,
easy-to-read operation
indicators and shows
boiler status together
with fault codes, in the
unlikely event of
a problem.
Low lift weight
of 43 kg offers easy
installation.
Compact dimensions of
height 687mm, width
397mm and depth
290 mm and no
compartment ventilation
required, ensure kitchen
cupboard fit and provide
siting flexibility.
`Self-adjusting' feature
reduces time and cost of
installation, and makes
installation much
simpler.
Hinged control PCB box
with easy access to
connections for
simplified servicing and
installation.
Optional programmer
Digital display with 7 day
programming offering 3 periods/day.
Optional remote mounting capability.
`Downward firing'
pre-mix burner
for greater reliability,
ensuring lower Nitrogen
Oxide emissions
(environmentally friendly).
Easy-to-wire mains
electrical connection
makes installation easier.
Fully modulating DHW outputs
giving flow rates of 9.6, 12 and
14.4 l/min at 35ºC temperature
rise.
isar HE-technical data
11
PERFORMANCE DATA
The Ideal isar HE combination boiler
Installation tips
Ideal recommend that a minimum
heating load of 3,000 Btu/h be
controlled using a room thermostat,
leaving all other rooms capable of being
controlled by TRVs.
The boiler has a cast aluminium-silicon
alloy heat exchanger, therefore suitable
water treatment should be applied to
the system.
These boilers require a permanent live
electrical supply.
A DHW flow restrictor is incorporated
within the boiler, automatically
controlling the DHW flow. This
eliminates the requirement for any
installer adjustments.
Siting options
Loft
Utility Room
Optional remotely mountable user
controls, compact dimensions and a
highly flexible fluing system allow the
isar HE to be easily sited.
Model
isar HE 24
isar HE 30
isar HE 35
Output
DHW
kW
8.8 - 23.4
8.8 - 29.3
8.8 - 35.2
Btu/h
30,000 - 80,000
30,000 - 100,000
30,000 - 120,000
Flow Rate
l/min
9.6
12.0
14.4
CH
kW
8.8 - 23.4
8.8 - 23.4
8.8 - 23.4
Btu/h
30,000 - 80,000
30,000 - 80,000
30,000 - 80,000
SEDBUK rating
A
A
A
NOX Class
5
5
5
INSTALLATION DATA
CLEARANCE DATA
The following clearances are required for installation, servicing and replacement of parts.
Front of boiler
Sides of boiler
Top of boiler
Bottom of boiler
450 mm
5 mm
165 mm**
100 mm
Minimum clearance required at bottom of boiler for servicing is 100 mm, additional clearance will be
required for installation, depending upon site conditions.
**More clearance required when fitting fluing to the side.
PIPEWORK CONNECTIONS AND PRODUCT DIMENSIONS
Flue pluming is a by-
product of efficiency.
Please be aware of
terminal positions to
avoid complaints (see
pages 16-23,
fluing options).
Note: This appliance is not suitable for external installation. The wall on which the boiler is being mounted
must be able to support its total weight. The wall will not require special protection, but if the unit is being
fitted in a timber-frame building the guidelines set out in IGE/UP/7:1998 should be observed.
Fascia can be removed for cupboard installations. Width: 390mm, depth: 278mm. *Add 32 mm with stand off brackets fitted
This product has an
energy rating of A
on a scale of A-G.
For more information see
www.sedbuk.com
SEDBUK rating
A
Gas supply connection
inches
Rc
1
/
2
(
1
/
2
" BSP female)
CH flow connection
mm
22 compression*
CH return connection
mm
22 compression*
Pressure relief valve
inches
Rc
1
/
2
(
1
/
2
" BSP female)
Expansion vessel volume
litres
8
Condensate drain
mm
21.5
Electrical supply
V/Hz
230/50
DHW inlet connection
mm
15 compression
DHW outlet connection
mm
15 compression
Power consumption
w
148 (isar HE 35 152w)
Fuse rating
A
3
Water content
litres
2
Maximum lift weight
kg
43
Total packed weight
kg
50
Flue terminal diameter
mm
100
S trap depth
mm
52
*For outputs exceeding 18 kW (60,000 Btu/h), 28 mm primary pipework will be required.
For full technical details please refer to the Installation and Servicing Instructions provided with the product.
12
13
istor HE
Central Heating &
Unvented Storage System
Naturally they are designed for fast and easy installation, whilst good accessibility
minimises service and maintenance. Space is freed up in the property due to their
compact design, whilst the householder also benefits by having an appliance capable of
giving mains pressure hot water from more than one outlet simultaneously. The choice of
two models provides these benefits for larger properties.
The many flue options available with the Ideal high-efficiency ranges allow more siting
options for this flexible product.
Application and usage
The istor HE offers tremendous flexibility in where it can be sited, freeing kitchen space if
installed in the airing cupboard for example. That type of siting is made easier by 100mm
concentric or a choice of 80mm and 60mm diameter twin-duct flue systems. More
awkward installations can now be handled with the optional condensate drain pump kit.
Rapid installation is assisted by thoughtful features such as a pre-piping frame, allowing
pipework to be made before fitting the unit. The water controls are all supplied inbuilt
requiring no extra space or time. Further ensuring that the istor HE is a truly complete
unit, a programmer and immersion heater all come fitted as standard.
The istor HE in operation
The units are automatically controlled with a fanned flue and no cupboard ventilation is
required. High-efficiency in operation is always maintained as the boiler modulates to
match the load applied.
Central heating
The boiler will fire to meet the heating requirements of the house as a normal system.
Domestic hot water
The cylinder contents (80 or 120) litres are immediately available for use and are blended
by the integral thermostatic mixing valve (settings 30-65ºC) to suit the householder. The
boiler will fire to replenish the cylinder or for a few seconds to maintain temperature.
Even after the full contents have been used, hot water is still available at reduced rate.
The cylinder is rapidly replenished as soon as DHW draw stops via the high recovery
cylinder coil.
The Ideal istor HE system store boiler
The istor HE system storage units take the provision of both central heating and
plentiful supplies of hot water to a new level. This is achieved by combining a
high-efficiency boiler and unvented cylinder in one unit with all necessary
controls. That also means a dry loft for simplicity and peace of mind.
istor HE
24-25
16-23
Please note: high level flue kit information is on pages 50-51
14-15
14-15
Pictures are representational of installations but always check with your installer for guidance on pipework etc.
14
Note: A pressure reducing valve (including filter)
is supplied for fitting externally to the appliance.
CH pressure gauge user
accessible pressure
gauge to monitor
system pressure.
Programmer 2 channel
programmer as standard
for independent selection of
CH & DHW on/off times.
Pressure relief valves for
cylinder protection.
Thermostatic mixer valve
controls DHW outlet
temperature. User adjustable
between 30 - 65ºC.
Heat engine based on the
fully modulating icos HE
boiler with outputs to CH
from 8.8 to 24 kW (30,000
to 80,000 Btu/h).
CH filling loop pre-fitted
filling loop to fill CH
circuit.
Fluing multi choice flue
variants for a wide range
of applications.
Installation Supplied as 2
separate module packages
for ease of handling and
installation.
DHW expansion vessel 19
litre vessel incorporated
within the appliance for
cylinder protection.
Pump & auto air vent
siting of pump and
automatic air vent
provide trouble free
filling of system.
Diverter valve
3 way diverter valve
operating with DHW
priority to maximise hot
water supply.
Alpha-numeric diagnostic
readout gives essential
easy to read operation
indicators and fault codes
in the unlikely event of a
problem.
CH expansion vessel
8 litre vessel for sealed
system CH incorporated
within the appliance.
Pre-piping frame
all service connections
can be made prior to
appliance installation.
istor HE technical data
15
PERFORMANCE DATA
INSTALLATION DATA
Model
istor HE 260
istor HE 325
Gas supply connection
inches
Rc
1
/
2
Rc
1
/
2
CH flow connection
mm
22*
22*
CH return connection
mm
22*
22*
Pressure relief valve
mm
15
15
CH Expansion vessel volume
litres
8
8
Condensate drain
mm
21.5
21.5
DHW inlet connection
mm
15
15
DHW outlet connection
mm
22
22
DHW delivery temperature
ºC
30 - 65
30 - 65
Water content
CH
litres
2
2
Water content
DHW
litres
80
120
Electrical supply
V/Hz
230/50
230/50
Power consumption
W
148
148
Fuse rating
A
3
3
Maximum lift weight
Boiler
kg
55
55
Maximum lift weight
Cylinder
kg
59
65
Total packed weight
Boiler
kg
58.5
58.5
Total packed weight
Cylinder
kg
66
73
Flue terminal diameter
Concentric
mm
100
100
Twin duct
mm
80 or 60
80 or 60
*For outputs exceeding 18 kW (60,000 Btu/h), 28 mm primary pipework will be required.
CLEARANCE DATA
The following clearances are required for installation, servicing and replacement of parts.
Front of boiler
Sides of boiler
Top of boiler
450 mm
5 mm
165 mm**
**More clearance required when fitting flue to the side.
PIPEWORK
CONNECTIONS
AND PRODUCT
DIMENSIONS
Flue pluming is a
by-product of
efficiency. Please be
aware of terminal
positions to avoid
complaints (see
pages 16-23,
fluing options).
Note: This appliance is not suitable
for external installation.
Model
istor HE 260
istor HE 325
Output
DHW
kW
8.8 - 29.3
8.8 - 29.3
Btu/h
30,000 - 100,000
30,000 - 100,000
Flow Rate
l/min*
35
35
CH
kW
8.8 - 23.4
8.8 - 23.4
Btu/h
30,000 - 80,000
30,000 - 80,000
Recovery times**
mins
9
12
SEDBUK rating
A
A
NOX Class
5
5
*Practical maximum with suitable mains supply **Recovery times are after 70% draw off, from 15ºC
The Ideal istor HE system store boiler
Installation tips
Ideal recommend that a minimum
heating load of 3,000 Btu/h be
controlled using a room thermostat,
leaving all other rooms capable of being
controlled by TRVs.
The boiler has a cast aluminium-silicon
alloy heat exchanger, therefore suitable
water treatment should be applied to
the system.
These boilers require a permanent live
electrical supply.
Siting options
Loft
Utility Room
Compact dimensions and a highly
flexible fluing system allow the istor HE
to be easily sited.
This product has an
energy rating of A
on a scale of A-G.
For more information see
www.sedbuk.com
SEDBUK rating
A
For full technical details please refer to the Installation and Servicing Instructions provided with the product.
5
10
15
20
25
30
35
40
45
50
5
10 15 20
25 30
35 40
45
50 55
60
AIR PIPE LENGTH (m)
F
L
U
E
P
I
P
E
L
E
N
G
T
H
(
m
)
R
F
8
7
1
1
Note. Dotted line is example - see Frame 4
IMPORTANT.
Flue and air pipe length combinations
must be within the red area.
FIG. 1 Air and flue length combination graph
80 mm twin flue system
5
10
15
20
5
10
15
20
AIR PIPE LENGTH (m)
F
L
U
E
P
I
P
E
L
E
N
G
T
H
(
m
)
R
F
8
7
1
4
IMPORTANT. Flue and air pipe length
combinations must be within the red area.
Note. Dotted line is example - see Frame 3
FIG. 2 Air and flue length combination graph
60 mm twin flue system
Twin-pipe systems
16
fluing options
The HE combination range from Ideal
boilers benefits from a wide variety of
fluing options, making it possible for
the installer to fit each unit safely and
unobtrusively in almost any situation.
The following information sets out the
alternatives that are available and
demonstrates the siting flexibility that
is an inherent part of all our boilers.
The Ideal HE combination range comes
with a choice of concentric or twin-
pipe fluing options.
Twin-pipe fluing
Various twin-pipe options are available,
in both 80 mm and 60 mm diameters,
to assist in the termination of the flue
where the boiler is installed in a location
remote to an outside wall. These
options allow for separation of the air
supply from the pipe that discharges
the flue gases. All twin pipe flue
installations must be fitted with the
condensate drain trap supplied.
80 mm twin-pipe system
The maximum combined flue length
is 60 metres. The following graph
(FIG. 1) demonstrates the allowable
lengths for the air supply and flue gas
pipes. This system can be used for
both horizontal and vertical
applications.
60 mm twin-pipe system
The maximum combined flue length
is 18 metres. The following graph
(FIG. 2) demonstrates the allowable
lengths for the air supply and flue
gas pipes. This system can be
used for horizontal applications only.
Concentric flue systems
Maximum flue lengths:-
isar HE 24, 30
6 m
7.5 m
22 m
isar HE 35
3 m
7.5m
22 m
istor HE
6 m
7.5 m
22 m
*Each 90° elbow used is at the expense of 1000 mm of straight flue run, and each 45° elbow is
used at the expense of 600 mm of straight flue run.
Typical combined primary and secondary length. See installation instructions for more details.
Note: The flue deflector kit is used at the expense of 1000mm of straight flue run.
H
O
R
I
Z
O
N
T
A
L
*
V
E
R
T
I
C
A
L
*
P
O
W
E
R
E
D
V
E
R
T
I
C
A
L
High level flue outlet kit
The plume of vapour at a high efficiency flue terminal can be a nuisance in some
installations. A range of solutions to provide a high level flue terminal out of normal
view are available. See pages 50 and 51 for information.
17
Minimum dimensions of flue terminal
positions
KEY TO ILLUSTRATION
Terminal Position
Fan Models
Min. Spacing
1
Directly below an openable
window or other opening
e.g. air brick
300 mm
2
Below gutters, drain pipes
or soil pipes
25 mm*
BS5440-1 2000 75mm
3
Below eaves
25 mm*
BS5440-1 2000 200mm
4
Below balconies or car
port roof
25 mm*
BS5440-1 2000 200mm
5
From vertical drain pipes
or soil pipes
25 mm*
BS5440-1 2000 150mm
6
From an internal or external
corner or to a boundary
alongside the terminal
25mm*
BS5440-1 2000 300mm
7
Above ground, roof
or balcony level
300 mm
8
From a surface or a
boundary facing a terminal
600 mm
9
From a terminal
facing a terminal
1200 mm
10
From an opening in a
car port into a dwelling
1200 mm
11
Vertically from a terminal
on the same wall
1500 mm
12
Horizontally from a
terminal on the same wall
300 mm
Vertical flues
13
Above a pitched or flat roof
(to base of terminal)
300 mm
14
From single wall face
(Flat roof)
600 mm
(Pitched roof)
1000 mm
From corner wall faces
1000 mm
Table corresponds to BS5440: Part 1 : 2000
*Note: Only one reduction down to 25mm is allowable
per installation otherwise BS5440-1 2000 dimensions
must be followed.
It must always be borne in mind that the HE range flues
plume and that special consideration should be given to
terminal position.
Concentric Flue Kits
Part No.
Telescopic B Pack Flue
203164
Horizontal flue terminal (600mm long)
203128
Flue extension kit 60/100 mm (Pack D: 1000 mm long)
203129
Roof flue kit
203132
Powered vertical flue kit
203136
45° Elbow kit 60/100 mm diameter (pair)
203131
Universal weather collar 100 mm diameter
152258
Flat roof weather collar 100 mm diameter
152259
Flue extension pipe 1m x 80mm diameter (pair)
203142
Powered vertical flue terminal
203134
90° Flue elbow kit 60/100 mm
203130
Flue finishing kit
155988
Vertical connector
203135
Flue deflector kit
203137
80 mm Twin-pipe System
Part No.
Twin-pipe extension kit 0.5m x 80mm diameter
203157
Twin-pipe extension pipe 1m x 80mm diameter (pair)