Mini SE/HE
| Boiler in standby mode - no call for heating or hot water | ||
| Indicating Central Heating operation | Not fault with boiler external controls calling for heat | |
| Indicating Domestic Hot water operation | Not fault with boiler hot water tap open. If customer confirms no tap open book callout | |
| Boiler in frost protection mode | Boiler will go into frost protection mode if temperature drops below 4 deg C | |
| DHW operation - Excessive temperature in primary circuit | ||
| Faulty Central heating thermistor | Book callout | |
| Faulty DHW thermistor | Book callout | |
| Faulty flue thermistor | Book callout | |
| Faulty primary circuit - lack of water flow through boiler | Check pressure gauge - 1-1.5 bar/check for air in system - bleed radiators etc. If all checked book callout | |
| Faulty air pressure switch | Check black plugs are fitted on top left of boiler(soemtimes knocked off during installation) - if ok book callout | |
| Boiler failed to ignite - ignition lockout | Check gas supply, if OK book callout | |
| Overheat thermostat lockout | Attempt to reset boiler by press red reset button. Overheat condition may occur due to air in system or poor circulation. - If all OK book callout | |
| Flue thermistor lockout | Probably due to lack of servicing, condesate backing up into boiler. If boiler recently installed or has been serviced - book callout | |
| Lack of power supply or faulty PCB | Check fused spur - if OK book callout | |
| Faulty PCB | Book callout |