Elise, Esprit, Icos, Isar, Istor NOx emission levels

New construction is increasingly being built to meet the maximum level of the Code for Sustainable Homes (previously EcoHomes) scheme. This is a points based environmental rating scheme used to illustrate the quality of the overall site design. It was created by the Building Research Establishment.

Maximum credit points for boilers are earned when NOx (nitrogen oxides) emission levels are less than 40 mg/kWh dry air free. This level exceeds the best required by British Standards, usually referred to as Class 5.

The Ideal HE range of SEDBUK A appliances has been fully tested in conformance with the relevant Standards to establish weighted values taking into account the boiler modulation, and all boilers now achieve NOx levels of less than 40mg/kWh. These results have been independently verified by Advantica.

Therefore the following boilers: Esprit HE, elise H, icos HE, isar HE, icos system HE and istor HE will achieve maximum credits under the Code for Sustainable Homes scheme.

Measured results are as follows:

Model NOx (mg / kWh)* NOx (ppm)*
icos HE12 15.5 8.8
icos HE15
icos System HE15
elise H15
16 9.1
icos HE18 13.3 7.5
icos HE24
icos System HE24
elise H24
esprit HE24
esprit HE30
isar HE24
isar HE30
istor HE260
istor HE325
19.2 10.9
esprit HE35
isar HE35
17 9.6
icos HE30 19.7 11.2
icos HE36 24.5 13.9

* All figures are quoted at dry at 0% Oxygen.